Electrical Projects All new tools, properly connected, use the green wire as the safety ground. This wire is attached to the metal case of the tool at one end and to the polarized grounding pin in the connector at the other end. It normally carries no current, but is used only when the tool insulation fails, in which case it short circuits the electricity around the user to ground and protects him from shock. The green lead must never be mixed with the black or white leads which are the true current-carrying conductors.

Check the resistance of the grounding system with a low reading ohmmeter to be certain that the grounding is adequate (less than 1 ohm is acceptable). If the resistance indicates greater than 1 ohm, use a separate ground strap.

Some old installations are not equipped with receptacles that will accept the grounding plug. In this event, use one of the following methods:

1. Use an adapter fitting.

2. Use the old type plug and bring the green ground wire out separately.

3.   Connect an independent safety ground line. When using the adapter, be sure to connect the ground lead extension to a good ground. (Do not use the center screw which holds the cover plate on the receptacle.) Where the separate safety ground leads are externally connected to a ground, be certain to first connect the ground and then plug in the tool. Likewise, when disconnecting the tool, first remove the line plug and then disconnect the safety ground. The safety ground is always connected first and removed last.





Page 1 2
Home > Electrical Projects > Grounding Of Equipment





Menu:
Electric Current
Effects Of Electric Shock
General Safety Precautions
High Voltage Safety Precautions
Grounding Of Equipment
Preventing Electrical Fires
Firefighting
Shock
Tools And Components
Repairs


Related Searches:
discontinued
ohm
independent
conductors
reading

October 13, 2008