Reassembly

Reverse the disassembly procedure. Use a good epoxy to hold the handle to body if weld breaks. Wet the gasket with alcohol (both inside and outside) as a lubricant. Install the gasket on the tank and insert both together into the body.


Final Tests

Apply a high voltage of 1200V for 1 second or 1000V for 1 minute between the prongs on the cord set and the tank.

(Remove the plug in the base to gain access to the tank surface.) Plug the unit at room temperature into a 120V power source. The temperature control must start cycling within 3 minutes.